Controller PFC100; 2nd Generation; 2 x ETHERNET
750-8111
Technical data
| Communications | Modbus TCP master/slave Modbus (UDP), WagoAppPlcModbus Library Modbus (RTU), WagoAppPlcModbus Library ETHERNET EtherNet/IPTM Adapter (slave) EtherNet/IPTM Scanner EtherCAT® Master OPC UA Server/Client OPC UA Pub/Sub (can be installed later) MQTT BACnet/IP, requires an additional license Telecontrol protocols, requires an additional license |
| ETHERNET protocols | DHCP DNS NTP FTP FTPS SNMP HTTP HTTPS SSH |
| Telecontrol protocols | IEC 60870 (additional license as slave or master) IEC 61850 (additional license as Client or Server) DNP3 (additional license as Slave or Master) |
| Visualization | Web-Visu |
| Operating system | Real-time Linux (with PREEMPT_RT patch) |
| CPU | Cortex A8; 600 MHz |
| Programming languages per IEC 61131-3 | Instruction List (IL) Ladder Diagram (LD) Function Block Diagram (FBD) Continuous Function Chart (CFC) Structured Text (ST) Sequential Function Chart (SFC) |
| Programming environment | CODESYS V3.5 |
| Configuration options | CODESYS V3 CODESYS Library Ethernet Settings WAGO-I/O-CHECK Web-Based Management |
| Transmission rate | ETHERNET: 10/100 Mbit/s |
| Transmission medium (communication/fieldbus) | ETHERNET: Twisted pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length |
| Main memory (RAM) | 512MB |
| Internal memory (flash) | 4096MB |
| Non-volatile hardware memory | 128kbyte |
| Program memory | 32 MB (Program and data memory (dynamically distributed)) |
| Data memory | 128 MB Program and data memory (dynamically distributed) |
| Non-volatile software memory | 128.kbyte |
| Type of memory card | microSD up to 32 GB (all guaranteed properties only valid with WAGO’s memory card) |
| Memory card slot | Push-push mechanism; cover lid (sealable) |
| Number of modules per node (max.) | 250 |
| Number of modules without a bus extension (max.) | 64 |
| Input and output process image (internal) max. | 1000 words/1000 words |
| Input and output process image (Modbus®) max. | CODESYS V3: 32000 words/32000 words |
| Drift – system clock (25 °C) | 20ppm |
| Buffer time Real Time Clock (25 °C) | 7Tage |
| Indicators | LED (SYS, RUN, I/O, USR) red/green/orange: Status of system, program, local data bus, status programmable by user (can be used via CODESYS library); LED (A, B) green: Status of system power supply, field supply |
| Supply voltage (system) | 24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection) |
| Input current (typ.) at nominal load (24 V) | 550mA |
| Total current (system supply) | 1,700mA |
| Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts |
| Current carrying capacity (power jumper contacts) | 10A |
| Number of outgoing power jumper contacts | 3 |
| Isolation | 500 V system/field |
Connection data
| Connection technology: communication/fieldbus | Modbus (TCP, UDP): 2 x RJ-45 |
| Connection technology: system supply | 2 x CAGE CLAMP® |
| Connection technology: field supply | 6 x CAGE CLAMP® |
| Connectable conductor materials | Copper |
| Connection type | System/field supply |
| Solid conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Connection technology: device configuration | 1 x Male connector; 4-pole |
Physical data
| Width | 61.5 mm / 2.421 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 71.9 mm / 2.831 inches |
| Depth from upper-edge of DIN-rail | 64.7 mm / 2.547 inches |
Mechanical data
| Mounting type | DIN-35 rail |