2-conductor fuse terminal block; with pivoting fuse holder; for glass cartridge fuse ¼” x 1¼”; without blown fuse indication; for DIN-rail 35 x 15 and 35 x 7.5; 4 mm²; CAGE CLAMP®; 4,00 mm²; gray
Item no. 281-623
2-conductor fuse terminal block
Ratings (note) | Electrical ratings are given by the fuse. |
Power loss (max.) Pl (max.) (note) | When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers. |
Power loss Pl max. overload and short-circuit protection (individual arrangement) | 2.5W |
Power loss Pl max. overload and short-circuit protection (group arrangement) | 1.6W |
Power loss Pl max. short-circuit protection (individual arrangement) | 4W |
Power loss Pl max. short-circuit protection (group arrangement) | 2.5W |
Fuse receptacle | pivoting |
Fuse type | Cylindrical fuse; ¼” x 1¼” |
Clamping units | 2 |
Total number of potentials | 2 |
Number of levels | 1 |
Connection technology | CAGE CLAMP® |
Actuation type | Operating tool |
Connectable conductor materials | Copper Aluminum |
Connectable conductor materials (note) | Terminating Aluminum Conductors WAGO Spring-Clamp Terminal Blocks are suitable for solid aluminum conductors up to 4 mm²/12 AWG if WAGO “Alu-Plus” Contact Paste 249-130 is used for termination. “Alu-Plus” Contact Paste Advantages:
Using terminal blocks with CAGE CLAMP® Spring Pressure Connection Technology, aluminum conductors must first be cleaned with a blade and then immediately inserted into the clamping units filled with “Alu-Plus” contact paste. It is also possible to apply WAGO “Alu-Plus” additionally on the whole surface of the aluminum conductor before termination. Please note that the nominal currents must be adapted to the reduced conductivity of the aluminum conductors: |
Solid conductor | 0.08 … 4 mm² / 28 … 12 AWG |
Fine-stranded conductor | 0.08 … 4 mm² / 28 … 12 AWG |
Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
Wiring direction | Front-entry wiring |
Width | 10 mm / 0.394 inches |
Height | 60 mm / 2.362 inches |
Depth from upper-edge of DIN-rail | 60 mm / 2.362 inches |
Design | angled |
Mounting type | DIN-35 rail |
Marking level | Center marking |
Note (material data) | Information on material specifications can be found here |
Color | gray |
Material group | I |
Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 |
Fire load | 0.376MJ |
Weight | 19.5g |